ASTM D5946/ISO 15989 WCA Measurement Corona-Treated Polymer Films
Water contact angle test for corona treated polymer film. Fully compliant: the Dropometer runs the measurement this method describes.
CONTENT HUB
An index of the ASTM, ISO, TAPPI, AATCC, IPC, IEC, EN, API and USP standards for contact angle, surface tension, surface energy and wettability. Each standard page explains what it specifies, how the test is run and where the Dropometer fits. The compliance tier describes measurement equivalence, not a formal accreditation.
Dropometer measures the property this standard specifies, using an equivalent method.
ASTM D5946/ISO 15989 WCA Measurement Corona-Treated Polymer Films
Water contact angle test for corona treated polymer film. Fully compliant: the Dropometer runs the measurement this method describes.
ASTM D7334
Advancing contact angle test for coatings, substrates and pigments. Fully compliant: the Dropometer reads the advancing angle by adding liquid through the needle.
DIN EN 828:2013
Surface free energy from the contact angles of several liquids, for adhesives and bonding. Fully compliant: the Dropometer measures the angles and OWRK runs in the free calculator.
EN ISO 19403-3
Pendant drop surface tension of paints and liquid coatings. Fully compliant: the Dropometer runs the measurement this method describes.
EN ISO 19403-6
Advancing and receding contact angle on paint and varnish by changing drop volume. Fully compliant: the Dropometer runs the measurement this method describes.
FDA 510(k) Guidance: Determining CMC by Surface Tension
FDA 510(k) guidance asking contact lens daily cleaners to report surface tension and CMC. Fully compliant: the Dropometer pendant drop tensiometer runs Chem-Appendix B.
IEC TS 62073
IEC guidance on measuring insulator hydrophobicity. Fully compliant with Method A, the contact angle method. Methods B and C are visual.
ISO 19403-2: Paints and Varnishes
Surface free energy of paints and coatings from contact angles. Fully compliant: the Dropometer measures the angles and you run OWRK in our free calculator.
SEMI/ASTM D7490-13
Two liquid contact angle method for the dispersive and polar surface energy of coatings, substrates and pigments. Fully compliant: the Dropometer runs the measurement this method describes.
TAPPI T 458 cm-24 / ASTM D724
Water contact angle test for paper ruling and writing quality. Fully compliant: the Dropometer runs the measurement this method describes.
Dropometer supports part of this standard’s workflow or a related measurement.
AATCC TM 79
Drop absorbency time on textiles. Partially compliant: the Dropometer times drop absorption on fabric from a side view at 10 frames per second, an alternative to the specular…
AATCC TM118
Oil repellency test for finished fabric with graded hydrocarbon liquids. Partially compliant: the Dropometer checks the test oils by pendant drop and measures their contact angle on the…
AATCC TM193
Water/alcohol repellency test for finished fabric with graded test liquids. Partially compliant: the Dropometer checks the test liquids by pendant drop and measures their contact angle on the…
API RP 40
Recommended practices for core analysis, including preserving and measuring wettability. Partially compliant: the Dropometer reads oil and brine contact angle on flat rock or mineral surfaces with the…
ASTM C813
Water contact angle test for hydrophobic contamination on glass. Partially compliant: the Dropometer reads angles from 10°, not the lowest angles on very clean glass.
ASTM D1331
Ring and plate surface tension test for surfactant solutions, paints and solvents. Partially compliant: the Dropometer measures surface tension by pendant drop, and interfacial tension with the optional…
ASTM D1417
Test methods for synthetic rubber latex, including surface tension. Partially compliant: the Dropometer measures latex surface tension by pendant drop, an alternative to ring or plate.
ASTM D2285
Withdrawn drop weight method for insulating oil against water. Partially compliant: the Dropometer measures the same interfacial tension by pendant drop with the optional cuvette.
ASTM D2578
Wetting tension of polyethylene and polypropylene film with test solutions, the US dyne test. Partially compliant: the Dropometer measures wetting by contact angle and checks test solutions by…
ASTM D3825
Dynamic surface tension by fast bubbles, withdrawn 2016. Partially compliant: the Dropometer reads dynamic surface tension by pendant drop from about 0.1 s onward.
ASTM D7541-11
Critical surface tension of coatings, primers and plastics from a Zisman plot. Partially compliant: the Dropometer runs the drop and contact angle route, not the swab, pen or…
ASTM D8597
Contact angle wettability test with portable goniometers for coatings and parts. Partially compliant: the Dropometer runs the sessile drop measurement, not handheld readings on large parts.
ASTM D971 and IEC 62961
Ring method for insulating oil against water. Partially compliant: the Dropometer measures the same interfacial tension by pendant drop with the optional cuvette, at 60 s or 180…
ASTM F21
Atomizer test for hydrophobic surface films. Partially compliant: the Dropometer detects the same films by water contact angle, an alternative to the visual spray test.
ASTM F22
Water break test for hydrophobic surface films. Partially compliant: the Dropometer detects the same films by water contact angle, an alternative to the visual water break test.
ASTM G205
Guide to crude oil corrosivity: emulsion type, steel wettability and water phase corrosivity. Partially compliant: the Dropometer reads the oil and water contact angle on steel with the…
EN 14210
Ring or stirrup interfacial tension test for surfactant solutions against an oil, 4 to 50 mN/m. Partially compliant: the Dropometer measures interfacial tension by pendant drop with the…
EN 14370
Static surface tension of surfactant solutions by plate, stirrup or ring. Partially compliant: the Dropometer measures it by pendant drop, an alternative method.
EN 15802
Static water contact angle test for stone and treated heritage surfaces. Partially compliant: the Dropometer reads 10° to 175°, not untreated stone that absorbs the drop or reads…
IEC TR 62039
Selection guide for polymeric outdoor HV insulation materials. Partially compliant: the Dropometer reads the hydrophobicity transfer contact angle, not the electrical tests.
ISO 1409
Surface tension of polymer dispersions and rubber latex by ring or plate. Partially compliant: the Dropometer measures it by pendant drop, an alternative method.
ISO 14778
Water contact angle test for paper and board. Partially compliant: the Dropometer reads fixed time angles from about 0.1 s, not the 20 to 40 ms first reading.
ISO 19403-7:2024
Roll off angle and dynamic contact angles of a drop on a tilted paint film. Partially compliant: the Dropometer tilt stage runs 0 to 60°, with a fixed…
ISO 27448
Water contact angle under UV for photocatalytic self cleaning surfaces. Partially compliant: the Dropometer reads angles from 10° up; you supply the UV lamp and radiometer.
ISO 4311
CMC of anionic and non ionic surfactants from surface tension against log concentration. Partially compliant: the Dropometer gets the CMC by pendant drop, an alternative to plate, stirrup…
ISO 6889
Stirrup or ring interfacial tension test for surfactant solutions against a second liquid. Partially compliant: the Dropometer measures interfacial tension by pendant drop with the optional cuvette, an…
ISO 8296
Dyne level of plastic film by test inks, and the common 38 dyne guideline. Partially compliant: the Dropometer measures wetting by contact angle and checks test inks by…
TAPPI T 558
Automated contact angle and absorbency test for paper, board and film. Partially compliant: the Dropometer reads the 1.0 s and 10 s check points, not the 0.1 s…
USP ⟨1243⟩
Wetting of pharmaceutical powders, tablets, liquids and packaging. Partially compliant: the Dropometer measures contact angle, surface tension and surface energy by drop shape analysis, not every technique the…
Dropometer supports adjacent measurements that inform this standard’s workflow.
AATCC TM22: Water Repellency Spray Test
Water repellency spray test for textile fabrics, rated by visual comparison. Complements workflow: the Dropometer measures contact and sliding angle on fabric, not the spray rating.
API RP 13B
Field tests for water based and nonaqueous drilling fluids. Complements workflow: the Dropometer adds surface tension, contact angle and, with the optional cuvette, interfacial tension checks in the…
ASTM D3359
Cross cut and X cut tape test for coating adhesion on metal. Complements workflow: the Dropometer does not rate adhesion; it checks wetting on the bare surface before…
IPC J-STD-003
Solderability tests for printed boards: edge dip, wave, surface mount simulation, solder float and wetting balance. Complements workflow: the Dropometer adds flux surface tension and finish contact angle…
IPC-TM-650
IPC test methods for board cleanliness, SIR, solder mask and conformal coating. Complements workflow: the Dropometer adds a water contact angle check for non ionic films before coating,…
ISO 25178
Areal surface roughness parameters such as Sa and Sdr. Complements workflow: the Dropometer adds the contact angle that shows whether texture or chemistry drives wetting.
ISO 535
Cobb test for water absorptiveness of paper and board. Complements workflow: the Dropometer adds a water contact angle check on sizing; it does not measure the Cobb value.
TAPPI T 441
TAPPI T 441 Cobb test for water absorptiveness of sized paper and board. Complements workflow: the Dropometer adds a water contact angle check on sizing; it does not…